Background Magnetic Field Removal Standalone¶
Background field removal in QSM¶
The phase we measured in a GRE acquisition is affected by not only the brain tissue but also sources like B0 inhomogeneity and air sinus. In order to compute the susceptibility sources only contributed by the brain tissue, it is important to remove all the non-local field effect. Fortunately, the characteristic of the local field is different from that of the non-local field, it is possible to separate the two fields from the unwrapped total field. This standalone application is designed to solve the field separation problem.
Caution: It is crucial that the background field contribution is removed accurately in this stage. Otherwise, the remaining field due to background sources will be treated as part of the local field, degrading the quality of QSM result.
Structure of the application¶
This application consists of two panels:
- I/O panel, and
- Background field removal panel.
Description of each panel is given below:
I/O panel¶
The I/O panel is responsible for data input/output and data processing that is not specific to QSM.
Data input
There are two pathways to specify input in this application:
- Specify a directory that contains all essential data.
The essential data are:
Data Description Total field 3D fieldmap (a.k.a. total field map) in Hz ([x,y,slice]), must contain ‘fieldmap’ in the filename, e.g. fieldmap.nii.gz Header see SEPIA header for more information, must contain ‘header’ in the filename, e.g. header.mat Mask 3D signal mask, if provided, must contain string ‘mask’ in the filename, e.g. mask.nii.gz Warning
Please make sure the filenames follow the above rules (see also Data Input in Data Preparation) and no other files in the directory sharing the same string labels (i.e. ‘fieldmap’, ‘header’ and ‘mask’).
Warning
The rule of filename for the fieldmap is changed from ‘total-field’ to ‘fieldmap’ in v1.0 in accordance to BIDS specification.
- Specify the required data separately using the GUI buttons.
Note
The ‘Noise SD’ input is an optional input for ‘PDF’ algorithm. You can specify a 3D data that provides the noise standard deviation of the original phase data (e.g. noisesd.nii.gz derived from phase unwarpping step in SEPIA).
Output prefix
By default, the output files generated by SEPIA will be stored in a directory named ‘output‘ under the directory of the input files (i.e. ‘_/your/input/directory/output/_’). The prefix of the output filename is ‘Sepia‘. You can change the default output directory and prefix according to your preference. If the output directory does not exist, the application will create the directory.
Note
Make sure the ‘Output prefix’ field contains a full path of the output directory and a filename prefix.
Brain mask
You can specify a signal (brain) mask NIfTI file.
Note
A mask must be provided (either in the input directory or specified) in this standalone.
Background field removal panel¶
Method
Select a background field removal method. The method parameters will be displayed on the method panel.
Remove residual B1 field by
Option to remove potential field contributions originated from B1 by polynomial fitting or spherical harmonic fit.
Erode edge voxel(s)
Further remove the edge voxels from the brain mask. Useful when the local field is not reliably estimated on the brain edges. This operation is performed prior the ‘Remove potenital B1 residual phase’ operation (if selected).
Others¶
Load config
Import the method related settings specified in the SEPIA-generated config file to the SEPIA GUI. NO modification will be made in the I/O panel.
Start